Zenox

Case Study | Sainatha Hospital – Pune, India

Zenox MBVD PSA Oxygen Generator Performance

Zenox MBVD PSA Oxygen Generator Performance

Installed & commissioned on 17th November, the Zenox MBVD PSA Oxygen Plant (12 Nm³/hr) was evaluated over 30 days (720 hrs).

📊 Actual Operating Data

  • Net running hours: ~400 hrs
  • Oxygen produced: 3,299 Nm³
  • Compressor power: 11 kW
  • Power tariff: ₹14 / kWh

⚙️ Key Performance Metrics

  • Average production: 8.25 Nm³/hr (~69% of design load)
  • Specific power consumption: 1.33 kWh / Nm³
  • Oxygen generation cost: ₹18.7 per Nm³

Leave a Reply

Your email address will not be published. Required fields are marked *

Request A Call Back

    Zenox integrates cutting-edge air separation technologies into our products.

    Contact Us

    ISO-9001 & ISO 13485 Certified

    © 2025 Zenox Gas Systems Australia Pty Ltd